Fatek FBs-20MNR2-AC (FBs-20MN)

Fatek PLC Controller FBs-20MNR2-AC User Manual

Model: FBs-20MNR2-AC (FBs-20MN)

1. Úvod

This manual provides essential information for the proper installation, operation, and maintenance of the Fatek FBs-20MNR2-AC Programmable Logic Controller (PLC). The FBs-20MNR2-AC is a compact and powerful controller designed for industrial automation applications, offering a robust set of features for various control tasks.

Pred inštaláciou alebo obsluhou zariadenia si pozorne prečítajte tento návod, aby ste zaistili jeho bezpečné a efektívne používanie.

2. Kľúčové vlastnosti

  • 2 points digital differential input + 2 points digital differential output (920KHz 5VDC)
  • 10 points 24VDC digital input (4 points with 200KHz)
  • 6 Points relay digital output
  • 1 built-in RS-232 communication port (expandable up to 5 ports)
  • Built-in real-time calendar function
  • Wide power supply range: 100~240VAC
  • UL certified for safety and quality assurance

3. Bezpečnostné informácie

Dodržiavajte nasledujúce bezpečnostné opatrenia, aby ste predišli zraneniu osôb a poškodeniu zariadenia:

  • Elektrická bezpečnosť: Ensure all power is disconnected before wiring or performing any maintenance. Only qualified personnel should perform electrical installations.
  • Uzemnenie: Properly ground the PLC to prevent electrical shock and ensure stable operation.
  • Prostredie: Install the PLC in an environment free from excessive dust, moisture, corrosive gases, and extreme temperatures.
  • Vetranie: Ensure adequate ventilation around the PLC to prevent overheating.
  • Zapojenie: Use appropriate wire gauges and terminal connections. Do not exceed specified current ratings for inputs and outputs.
  • Núdzová zastávka: Always incorporate an independent emergency stop circuit in your system design.

4. Nastavenie a inštalácia

4.1 Fyzická inštalácia

The FBs-20MNR2-AC PLC is designed for DIN rail mounting within an industrial control panel. Ensure sufficient clearance for wiring and heat dissipation.

4.2 Zapojenie

Refer to the diagram below for terminal identification and wiring connections. Ensure all connections are secure and correct before applying power.

Fatek PLC Controller FBs-20MNR2-AC showing input/output terminals, power connections, and communication ports.

Obrázok 1: Predná strana view of the Fatek FBs-20MNR2-AC PLC, illustrating the various input (X), output (Y), power (AC100-240V, L, N, GND), and communication (TX, RX, PORTO) terminals. The status indicators (POW, RUN, ERR) are also visible.

4.2.1 Zapojenie napájania

  • Connect the AC power supply (100-240VAC) to the L (Line) and N (Neutral) terminals.
  • Connect the protective earth ground to the (Ground) terminal.

4.2.2 Digital Input Wiring (X0-X13)

  • The PLC features 10 points of 24VDC digital input (X0-X9), with X0-X3 supporting high-speed 200KHz operation.
  • Additionally, there are 2 points of digital differential input (X0-X1, X2-X3) for high-speed applications up to 920KHz.
  • Connect input devices (e.g., sensors, switches) to the respective X terminals.

4.2.3 Digital Output Wiring (Y0-Y9)

  • The PLC provides 6 points of relay digital output (Y0-Y5).
  • There are also 2 points of digital differential output (Y0-Y1, Y2-Y3) for high-speed applications up to 920KHz.
  • Connect output devices (e.g., relays, contactors, indicator lights) to the Y terminals. Observe the maximum current rating for each output.

4.2.4 Communication Port (PORTO, RS-232)

  • The built-in RS-232 port (PORTO) is used for programming the PLC and communicating with other devices.
  • Connect a programming cable from your computer to this port.

5. Návod na obsluhu

5.1 Zapnutie

After completing all wiring and ensuring safety, apply power to the PLC. The POW indicator LED should illuminate, indicating that the unit is receiving power.

5.2 Programovanie PLC

The Fatek FBs-20MNR2-AC is programmed using specific PLC programming software (e.g., WinProladder). Connect the PLC to your computer via the RS-232 port and use the software to develop, download, and monitor your control programs.

5.3 Indikátory stavu

  • POW (Power): Illuminates when power is supplied to the PLC.
  • RUN (Run Mode): Illuminates when the PLC is executing the user program.
  • ERR (Chyba): Illuminates or flashes to indicate a system error or fault. Refer to the troubleshooting section for details.
  • TX (prenos): Flashes when data is being transmitted via the communication port.
  • RX (príjem): Flashes when data is being received via the communication port.

6. Údržba

Regular maintenance ensures the longevity and reliable operation of your PLC.

  • Čistenie: Pravidelne čistite vonkajší povrch PLC mäkkou, suchou handričkou. Nepoužívajte rozpúšťadlá ani abrazívne čistiace prostriedky. Pred čistením sa uistite, že je vypnuté napájanie.
  • Kontrola terminálu: Regularly check all wiring terminals for tightness and corrosion. Loose connections can lead to intermittent operation or damage.
  • Environmentálna kontrola: Verify that the operating environment remains within specified conditions (temperature, humidity, dust).
  • Aktualizácie firmvéru: Skontrolujte údaje výrobcu website for any available firmware updates that may improve performance or address issues. Follow update instructions carefully.

7. Riešenie problémov

Táto časť poskytuje riešenia bežných problémov, s ktorými sa môžete stretnúť.

ProblémMožná príčinaRiešenie
PLC does not power on (POW LED off).No power supply, incorrect wiring, or internal fault.Check AC power connections (L, N, Ground). Verify power source. Ensure wiring is correct. If problem persists, contact support.
RUN LED is off, but POW LED is on.No program loaded, program error, or PLC in STOP mode.Download a valid program to the PLC. Check for program errors in the software. Ensure the PLC is set to RUN mode via software.
ERR LED is illuminated or flashing.System error, hardware fault, or critical program error.Connect to the PLC with programming software to read the error code. Consult the software manual for specific error meanings and solutions.
Inputs (X) are not responding.Incorrect wiring, faulty sensor, or input device not supplying correct voltage.Verify input device wiring and functionality. Check input voltage levels. Ensure input addresses in the program match physical connections.
Outputs (Y) are not activating.Incorrect wiring, faulty output device, or program logic error.Verify output device wiring and functionality. Check program logic for output activation conditions. Ensure output addresses in the program match physical connections.
Communication issues (e.g., cannot connect to PLC).Incorrect cable, wrong port settings, or driver issues.Ensure correct RS-232 cable is used. Verify COM port settings (baud rate, parity, data bits, stop bits) in software match PLC settings. Install or update USB-to-serial drivers if applicable.

8. Technické špecifikácie

ŠpecifikáciaHodnota
Číslo modeluFBs-20MNR2-AC (FBs-20MN)
Digitálne vstupy10 points 24VDC (4 points 200KHz), 2 points differential (920KHz 5VDC)
Digitálne výstupy6 points relay output, 2 points differential (920KHz 5VDC)
Komunikačné porty1 built-in RS-232 (expandable up to 5)
Napájanie100 ~ 240 V AC
Vstavané funkcieReal-time calendar
CertifikácieUL certifikované
Rozmery balenia4.5 x 4 x 4 palca
Hmotnosť položky1.01 libier
VýrobcaFatek
Dátum prvej dostupnosti27. septembra 2015

9. Záruka a podpora

For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Fatek directly. Technical support can be obtained through your authorized Fatek distributor or by visiting the official Fatek webstránka s kontaktnými informáciami a zdrojmi.

Always provide your product model number (FBs-20MNR2-AC) and serial number when seeking support.

© 2023 Fatek. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.