Secukey SK4-W

Secukey SK4-W Standalone Access Control System

Používateľská príručka

1. Úvod

This user manual provides comprehensive instructions for the installation, operation, and maintenance of the Secukey SK4-W Standalone Access Control System. Please read this manual carefully before installation and use to ensure proper functionality and safety.

The Secukey SK4-W is a robust, IP66-rated access control device designed for outdoor use, featuring RFID card and PIN code access. It is an ideal solution for securing doors, gates, and other entry points.

2. Produkt skončilview

2.1 Kľúčové vlastnosti

  • IP66 Waterproof and Anti-Vandal Design: Suitable for harsh outdoor environments.
  • Viacnásobné režimy prístupu: Supports RFID card only, PIN code only, or Card + PIN for enhanced security.
  • Vysoká používateľská kapacita: Manages up to 1000 users.
  • Integrated Relay: Built-in NO, NC, Com relay for direct door lock control.
  • Adjustable Output Times: Programmable lock output time (1-99 seconds) and alarm output time (1-3 minutes).
  • Wiegand 26-bit Interface: Supports external Wiegand readers, exit buttons, and alarms.
  • Režim západky: Allows the door or gate to remain open.
  • Wide Voltage Rozsah: Operates on 12~28V AC/DC.
  • Podsvietená klávesnica: Zaisťuje viditeľnosť v zlých svetelných podmienkach.
  • Odolná konštrukcia: Zinc alloy casing with powder coating.

2.2 Zahrnuté komponenty

  • 1 x Secukey SK4-W Standalone Access Control Device (RFID/PIN)
  • 1 x Master Add Card
  • 1 x Master Delete Card
  • 1 x Návod na použitie

2.3 Produkt Views

Predné view of the Secukey SK4-W access control system, showing the silver casing and black keypad with numbers 0-9, asterisk, and hash symbols.

Obrázok 1: Predná strana view of the SK4-W unit, highlighting the keypad and Secukey branding.

Šikmá predná časť view of the Secukey SK4-W access control system, showing the silver casing and black keypad.

Obrázok 2: Uhlové view of the SK4-W, providing a perspective of its slim profile.

Side view of the Secukey SK4-W access control system, emphasizing its compact design.

Obrázok 3: Strana view of the SK4-W unit.

Ďalšia strana view of the Secukey SK4-W access control system, showing the depth of the unit.

Obrázok 4: Ďalšia strana view of the SK4-W unit.

Späť view of the Secukey SK4-W access control system, showing the wiring harness for connections.

Obrázok 5: Späť view of the SK4-W unit, displaying the integrated wiring for installation.

3. Nastavenie a inštalácia

3.1 Montáž zariadenia

The SK4-W is designed for surface mounting. Choose a secure location near the door or gate, ensuring it is within reach for users and protected from direct impact. Use appropriate screws and wall plugs for the mounting surface.

3.2 Schéma zapojenia

The device requires a 12~28V AC/DC power supply (not included). Connect the wires according to the diagram provided in the full manual. Ensure all connections are secure and insulated to prevent short circuits.

  • Príkon: Connect to 12~28V AC/DC power source.
  • Lock Output (NO/NC/COM): Connect to your electric lock.
  • Výstup alarmu: Connect to an external alarm system (if applicable).
  • Wiegand In/Out: For connecting external Wiegand readers or other Wiegand devices.
  • Tlačidlo ukončenia: Connect a push-to-exit button for convenient egress.

For detailed wiring schematics, please refer to the comprehensive wiring diagram included in the product packaging.

4. Návod na obsluhu

4.1 Initial Setup and Master Cards

Upon first power-up, the device will be in factory default mode. Use the included Master Add Card and Master Delete Card to manage user access.

  • Pridávanie používateľov: Present the Master Add Card, then present the new user's RFID card or enter their PIN.
  • Odstránenie používateľov: Present the Master Delete Card, then present the user's RFID card or enter their PIN to be deleted.

4.2 Access Modes

The SK4-W supports three primary access modes:

  1. Card Only Mode: Users gain access by presenting a valid RFID card.
  2. PIN Only Mode: Users gain access by entering a valid 4-6 digit PIN code.
  3. Card + PIN Mode: Users must present a valid RFID card and then enter their corresponding PIN code for access. This mode offers the highest security.

Refer to the full programming guide for instructions on how to switch between access modes and manage user PINs.

4.3 Visitor PINs

The SK4-W supports up to 10 visitor PINs, which can be set to be valid for 1 to 10 uses. This feature is useful for temporary access for guests or service personnel.

Image illustrating the visitor PIN feature, showing a person using the access control system and a separate image of the device in water, indicating IP66 waterproof rating.

Figure 6: The SK4-W supports visitor PINs and is IP66 waterproof, suitable for outdoor installation.

4.4 Latch Mode

The latch mode allows the door or gate to remain unlocked for an extended period, which can be useful during peak hours or for maintenance. Consult the programming manual for activation and deactivation procedures.

5. Údržba

The Secukey SK4-W is designed for minimal maintenance due to its robust construction and IP66 rating. However, regular checks can prolong its lifespan and ensure optimal performance.

  • Čistenie: Wipe the keypad and casing s mäkkým, damp handričkou. Vyhýbajte sa abrazívnym čistiacim prostriedkom alebo rozpúšťadlám.
  • Kontrola pripojenia: Periodically inspect wiring connections for any signs of wear, corrosion, or loosening.
  • Aktualizácie firmvéru: Skontrolujte údaje výrobcu webstránku s dostupnými aktualizáciami firmvéru.
Image showing the Secukey SK4-W access control system embedded in ice, illustrating its ability to operate in extreme cold temperatures down to -40 degrees Celsius.

Figure 7: The SK4-W is designed to withstand extreme operating temperatures, from -40°C to 60°C.

6. Riešenie problémov

ProblémMožná príčinaRiešenie
Zariadenie sa nezapína.Žiadne napájanie; nesprávna hlasitosťtage; loose wiring.Check power connections and ensure correct 12~28V AC/DC supply. Verify wiring.
RFID karta nebola rozpoznaná.Card not enrolled; incorrect card type (not 125 KHz EM); damaged card.Ensure the card is properly enrolled. Verify it is a 125 KHz EM card. Try another card.
PIN kód nefunguje.Incorrect PIN; PIN not enrolled; device in card-only mode.Double-check the PIN. Ensure the PIN is enrolled. Verify the access mode setting.
Zámok dverí sa neaktivuje.Incorrect lock wiring (NO/NC); lock power issue; relay output time too short.Check lock wiring and power. Adjust the lock output time in settings.
Wiegand output issues.Incorrect Wiegand wiring; incompatible Wiegand device.Verify Wiegand 26-bit wiring. Ensure external device compatibility.

If the problem persists, please contact Secukey technical support for assistance.

Diagram illustrating Wiegand 26-bit input and output data signals, showing Data 0 and Data 1 waveforms with timing specifications.

Figure 8: Wiegand 26-bit input and output signal timing diagram.

7. Špecifikácie

AtribútHodnota
Číslo modeluSK4-W
ZnačkaSecukey
Rozmery (D x Š x V)13.0 x 5.6 x 2.3 cm
Hmotnosť500 gramov
FarbaStrieborná
Napájanie12 ~ 28 V AC / DC
Hodnotenie ochrany proti vniknutiu (IP).IP66 (Waterproof, Anti-Vandal)
Používateľská kapacitaAž 1000 používateľov
Dĺžka PIN kódu4 až 6 číslic
Typ karty125 KHz EM Card
Rozhranie WiegandWiegand 26-bit Input & Output
Uzamknúť výstupné zaťaženie3A Max
Zaťaženie výstupu alarmu3A Max
Prevádzková teplota-40 °C až 60 °C (-40 °C až 140 °F)
Prevádzková vlhkosť10 % až 90 % (bez kondenzácie)
CasinMateriálZinc Alloy with Powder Coating

8. Záruka a podpora

Secukey products are manufactured to high quality standards. For warranty information and technical support, please refer to the warranty card included with your product or visit the official Secukey webstránky.

Kontaktné informácie:

  • Výrobca: Secukey
  • Webmiesto: www.secukey.com (Naprampodkaz, skutočný odkaz sa môže líšiť)
  • Zákaznícky servis: Pozrite si obal produktu alebo webstránka s kontaktmi na regionálnu podporu.

Uschovajte si doklad o kúpe pre uplatnenie záruky.

© 2024 Secukey. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.