EasyByMall DSO510
DSO510 Compact Digital Oscilloscope User Manual
Model: DSO510
Brand: EasyByMall
1. Úvod
The DSO510 is a compact and versatile digital oscilloscope designed for convenient use in various environments. It features a real-time sampling rate of 48 MS/s and a 10 MHz bandwidth, making it suitable for both periodic analog and non-periodic digital signals. With its intuitive automatic function, users can quickly display measured waveforms without complex adjustments.
This manual provides detailed instructions on the setup, operation, and maintenance of your DSO510 oscilloscope. Please read it thoroughly before using the device to ensure proper and safe operation.
2. Vlastnosti produktu
- Vysoký výkon: 48 MS/s real-time sampling rate and 10 MHz bandwidth.
- Wide Voltage Rozsah: Opatrenia objtages up to ±400 V (X10 probe setting).
- Automatická funkcia: One-button auto-adjustment for quick waveform display.
- Integrovaný generátor signálu: Built-in 50 kHz function signal generator with various waveform types.
- Jasný displej: 2.8-inch 320x240 high-definition LCD screen.
- Prenosný dizajn: Compact size (99 x 68.3 x 19.5 mm) and lightweight (294g).
- Dlhá výdrž batérie: Built-in 1000 mAh lithium battery provides approximately 4 hours of continuous use.
- Nabíjanie cez USB: Convenient 5V/1A USB charging.
- Skladací stojan: Integrovaný stojan pre ovládanie bez použitia rúk.

Image: The DSO510 combines the functions of a 10MHz oscilloscope and a signal generator in one compact device.

Image: The DSO510 features a foldable stand for hands-free use and a gear toggle button for easy adjustments.
3. Obsah balenia
Overte si, či sú vo vašom balení všetky nižšie uvedené položky:
- 1 x DSO510 Host Unit
- 1 x P6100 High-Voltage Sonda
- 1 x Adaptér
- 1 x sonda s krokosvorkou
- 1 x Nabíjací kábel (USB)
- 1 x šnúrka
- 1 x Návod na použitie

Image: The DSO510 package includes the main unit, high-voltage probe, alligator clip probe, charging cable, adapter, and lanyard.

Image: The DSO510 can be conveniently charged via its USB port using the included charging cable.
4. Špecifikácie
| Parameter | Hodnota |
|---|---|
| Model | DSO510 |
| V reálnom čase Sampsadzba ling | 48 MS/s |
| Šírka pásma | 10 MHz |
| Vertikálna citlivosť | 10 mV/diel – 10 V/diel |
| Rozsah časovej základne | 50 ns/div – 20 s/div |
| Voltage Range (X1 Probe) | ±40 V (Vpp: 80 V) |
| Voltage Range (X10 Probe) | ±400 V (Vpp: 800 V) |
| Režimy spúšťania | Auto, Normal, Single |
| Trigger Edge | Rising Edge / Falling Edge |
| Coupling Modes | AC / DC |
| Calibration Square Wave | Frequency: 1 KHz; Duty Cycle: 50%; Amplitude: 3.3 V |
| Frekvencia generátora signálu | 0-50 kHz |
| Signal Generator Duty Cycle | 0-100% (Square wave, Sawtooth wave) |
| Generátor signálu Amplituda | 0.1-3.0 V |
| Priebehy signálov generátora signálu | Sine wave, Square wave, Sawtooth wave, Half wave, Full wave, Positive step wave, Inverse step wave, Exponential rise, Exponential fall, DC signal, Multi-audio, Sink pulse, Lorentz wave |
| Displej | 2.8" LCD displej, rozlíšenie 320 x 240 |
| Nabíjanie cez USB | 5 V / 1 A |
| Kapacita lítiovej batérie | 1000 XNUMX mAh |
| Rozmery (D x Š x V) | 99 x 68.3 x 19.5 mm |
| Hmotnosť | 294 g |
| Farba | Čierna a Modrá |

Image: Detailed specifications of the DSO510, highlighting its capabilities compared to similar models.
5. Nastavenie
5.1 Počiatočné nabíjanie
Before first use, fully charge the DSO510. Connect the included USB charging cable to the device's USB port and a 5V/1A USB power adapter (included) or a computer USB port. The charging indicator will show the charging status. A full charge takes approximately 4 hours and provides up to 4 hours of continuous operation.
5.2 Pripojenie sondy
Connect the BNC connector of the high-voltage probe (P6100) to the BNC input port on the DSO510. Ensure a secure connection by twisting the connector until it locks into place.
5.3 Probe Compensation (Recommended)
For accurate measurements, it is recommended to compensate the probe. Connect the probe tip to the calibration signal output (usually a 1KHz square wave) on the oscilloscope. Adjust the compensation trimmer on the probe until the square wave displayed on the screen has flat tops and bottoms without overshoot or undershoot.
5.4 Setting Probe Ratio
Ensure the probe ratio setting on the DSO510 matches the physical switch setting on your probe (1X or 10X). If the probe is set to 1X, the oscilloscope should also be set to 1X. A 1X setting measures voltages up to ±40 V, while a 10X setting measures up to ±400 V.
6. Návod na obsluhu
6.1 Zapnutie/vypnutie
Stlačením a podržaním tlačidla napájania (zvyčajne sa nachádza na boku alebo v spodnej časti) zariadenie zapnete alebo vypnete.
6.2 Automatic Measurement (AUTO Button)
For quick setup and display of a stable waveform, press the AUTOMATICKY button. The oscilloscope will automatically adjust the time base, vertical sensitivity, and trigger settings to display the measured waveform.
6.3 Navigating Menus and Adjusting Parameters
Use the navigation buttons (up/down/left/right) and the MODE button to navigate through menus and adjust parameters. The gear toggle button on the side can also be used for quick adjustments.
6.4 Režimy spúšťania
The DSO510 supports three trigger modes:
- Auto: Automatically triggers and displays the waveform, even if the signal is unstable.
- Normálne: Triggers only when the signal meets the trigger conditions. If no trigger occurs, the display remains unchanged.
- Single: Captures a single waveform when the trigger condition is met and then stops.
6.5 Waveform Adjustment After Pause
When the measurement waveform is paused (STOP mode):
- Prepínač MODE to "V H". The wheel button controls the time base (horizontal scale), and the up/down keys control the channel vertical sensitivity.
- Prepínač MODE to the arrow keys. The wheel button controls horizontal trigger movement, and the up/down keys control waveform vertical movement.

Image: Instructions on how to adjust the waveform display, including time base, vertical sensitivity, and horizontal/vertical positioning, after pausing the measurement.

Image: The DSO510 is capable of detecting various signal types, including pulse signals and other complex waveforms.
7. Indikátory na displeji
The DSO510 display provides various indicators to help you interpret measurements:
- Vertical Unit: Predstavuje objtage value for one large grid in the vertical direction.
- Trigger Mode Indicator: Displays "Auto" for automatic trigger, "Single" for single trigger, and "Normal" for normal trigger.
- Probe Ratio: Must be consistent with the 1X/10X switch setting on the probe handle.
- Input Coupling Mode Indicator: "AC" indicates AC coupling, "DC" indicates DC coupling.
- Trigger Voltage Indikátor: Shows the current trigger voltage úroveň.
- Trigger Position Indicator: Indicates the horizontal position of the trigger point.
- Baseline Indicator: Shows the 0V reference line.
- Time Base Indicator: Represents the duration for one large grid in the horizontal direction.
- Pause Indicator: "RUN" means operation, "STOP" means pause.
- Trigger Edge Indicator: Shows whether the trigger is set to rising or falling edge.
8. Funkcia generátora signálu
The DSO510 includes a built-in signal generator capable of producing various waveforms with adjustable frequency, duty cycle, and amplituda.
- Frekvenčný rozsah: 0-50 kHz
- Pracovný cyklus: 0-100% (for square and sawtooth waves)
- Amplituda: 0.1-3.0 V
- Typy priebehov: Sine wave, Square wave, Sawtooth wave, Half wave, Full wave, Positive step wave, Inverse step wave, Exponential rise, Exponential fall, DC signal, Multi-audio, Sink pulse, Lorentz wave.
To access and configure the signal generator, refer to the specific menu options on the device. Use the navigation buttons to select the desired waveform type and adjust its parameters.
9. Údržba
9.1 Čistenie
Zariadenie utrite mäkkou, suchou handričkou. Nepoužívajte abrazívne čistiace prostriedky ani rozpúšťadlá, pretože by mohli poškodiť zariadenie.asing or screen. Ensure the device is powered off before cleaning.
9.2 Skladovanie
Store the DSO510 in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity. When storing for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.
9.3 Starostlivosť o batérie
The device uses a built-in lithium battery. Avoid fully discharging the battery frequently. If the device will not be used for a long time, charge it every 3-6 months to prevent deep discharge.
10. Riešenie problémov
| Problém | Možná príčina | Riešenie |
|---|---|---|
| Zariadenie sa nezapne. | Slabá batéria; Tlačidlo napájania nebolo stlačené dostatočne dlho. | Nabíjajte zariadenie aspoň 30 minút. Stlačte a podržte tlačidlo napájania 3 – 5 sekúnd. |
| No waveform displayed or waveform is unstable. | Incorrect probe connection; Incorrect trigger settings; Signal too small or too large; Probe ratio mismatch. | Uistite sa, že sonda je bezpečne pripojená. Stlačte tlačidlo AUTOMATICKY button. Adjust vertical sensitivity (V/div) and time base (s/div). Verify probe ratio setting matches physical probe switch. |
| Waveform is distorted (e.g., rounded corners on square wave). | Probe compensation issue. | Perform probe compensation as described in Section 5.3. |
| Batéria sa rýchlo vybíja. | Aging battery; Continuous high-intensity use. | Ensure the device is fully charged. Reduce screen brightness if possible. If battery life significantly degrades, contact customer support. |
11. Záruka a podpora
Na tento produkt sa vzťahuje štandardná záruka výrobcu. Konkrétne záručné podmienky nájdete v dokumentácii dodanej pri nákupe alebo sa obráťte na svojho predajcu.
For technical support, troubleshooting assistance, or inquiries regarding replacement parts, please contact EasyByMall customer service. Please have your product model (DSO510) and serial number (if applicable) ready when contacting support.
Výrobca: EasyByMall
Číslo modelu: H2SV732SH08P7G239N2441
ASIN: B0DLBF6183