1. Úvod
This manual provides comprehensive instructions for the installation, operation, and maintenance of the GEYA GYHC 2P Modular AC Contactor. This device is designed for automatic control in household and light commercial electrical systems, offering reliable switching for various loads. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

Obrázok 1: Predná strana view of the GEYA GYHC 2P Modular AC Contactor, showing terminals and specifications.
2. Bezpečnostné informácie
POZOR: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working on the contactor or connected circuits.
- Ensure the main power supply is disconnected before any installation, wiring, or maintenance procedures.
- Overte si, že objtagmenovité napätie a prúd stýkača zodpovedajú požiadavkám aplikácie.
- Používajte vhodné osobné ochranné prostriedky (OOP), ako sú izolačné rukavice a ochranné okuliare.
- Nepoužívajte stýkač, ak sa zdá byť poškodený alebo bol vystavený vlhkosti.
- Všetky rozvody musia byť v súlade s miestnymi a národnými elektrickými predpismi.
3. Vlastnosti produktu
The GEYA GYHC 2P Modular AC Contactor offers robust performance and versatile application:
- Dual Current Ratings: Available in 40A and 63A options to manage medium to heavy household loads, including air conditioners, water heaters, and small motors.
- Triple Contact Configurations: Choose from 2NO (Normally Open for power switching), 2NC (Normally Closed for circuit isolation), or 1NO1NC (one Normally Open and one Normally Closed for control and feedback) to suit diverse application needs.
- Universal Voltage kompatibilita: Features a 220V/230V AC coil, compatible with standard 50/60Hz power grids.
- Modular DIN Rail Design: Compact automatic operation model designed for tool-free installation in standard distribution boxes, optimizing space.
- Aplikácia: Ideal for household and light commercial use, suitable for remote control of lighting, heating, ventilation, and other electrical appliances.

Image 2: Diagram illustrating the 2P 40A/63A contactor with 2NO, 2NC, and 1NO1NC contact configurations.
4. Inštalácia
The GEYA GYHC contactor is designed for easy installation on a standard 35mm DIN rail.
4.1 Montáž na DIN lištu
- Ensure all power to the distribution box is OFF.
- Locate an available section of the 35mm DIN rail within your electrical enclosure.
- Align the contactor's DIN rail clip with the rail.
- Press the contactor firmly onto the DIN rail until the clip engages and secures the device in place. Ensure it is stable and does not wobble.


Image 3 & 4: Side views illustrating the DIN rail mounting mechanism of the contactor.
5. Wiring and Operation
Proper wiring is essential for the correct function of the contactor. Refer to the wiring diagram on the product label and the following guidelines.
5.1 Pripojenie terminálu
- Power Terminals (1, 3, 2, 4): These are the main circuit terminals. Connect the incoming power to terminals 1 and 3, and the load to terminals 2 and 4.
- Svorky cievky (A1, A2): These terminals are for the control circuit. Connect the 220V/230V AC control voltage to A1 and A2 to energize the coil and switch the main contacts.

Obrázok 5: Uhlové view of the contactor, highlighting the main power and coil terminals.
5.2 Contact Configurations
The GYHC series offers different contact configurations:
- 2NO (2 Normally Open): Both main contacts are open when the coil is de-energized and close when the coil is energized.
- 2NC (2 Normally Closed): Both main contacts are closed when the coil is de-energized and open when the coil is energized.
- 1NO1NC (1 Normally Open, 1 Normally Closed): One contact is open and the other is closed when the coil is de-energized. They switch states when the coil is energized.

Image 6: Comparison of 2NC, 2NO, and 1NO1NC contactor variants.
5.3 Ručná prevádzka
Some models may include a manual override lever (often red or orange) at the bottom. This lever allows for manual switching of the contacts for testing or emergency situations. Always ensure power is disconnected before manual operation if there is any risk of electrical hazard.
6. Údržba
The GEYA GYHC contactor is designed for long-term, maintenance-free operation under normal conditions. However, periodic checks are recommended:
- Vizuálna kontrola: Pravidelne kontrolujte stýkač, či nevykazuje známky fyzického poškodenia, zmeny farby alebo uvoľnených spojov.
- Tesnosť svoriek: Ensure all terminal screws remain tight to prevent overheating and arcing.
- Čistota: Keep the contactor free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquids or solvents.
- Prevádzková kontrola: If safe to do so, periodically test the contactor's switching action to ensure it operates smoothly.
7. Riešenie problémov
If you encounter issues with your GEYA GYHC contactor, refer to the following troubleshooting guide:
- Stýkač sa nezapína:
- Skontrolujte, či je objem ovládaniatage (220V/230V AC) is present at terminals A1 and A2.
- Skontrolujte, či je ovládací obvod kompletný a či nie sú v ňom rozpojené žiadne spínače ani ochranné zariadenia.
- Inspect the coil for damage or signs of overheating.
- Stýkač sa zapne, ale záťaž nedostane napájanie:
- Ensure the main power supply is connected to terminals 1 and 3.
- Check for continuity across the main contacts (1-2 and 3-4) when the coil is energized.
- Verify that the load is correctly wired to terminals 2 and 4.
- Check for any tripped circuit breakers or blown fuses in the main circuit.
- Contactor Makes Humming Noise:
- A slight hum is normal for AC contactors. Excessive humming may indicate loose mounting, foreign objects, or an issue with the coil or armature.
- Ensure the mounting screws are tight and the contactor is securely seated on the DIN rail.
8. Špecifikácie
| Špecifikácia | Hodnota |
|---|---|
| Značka | GEYA |
| Číslo modelu | GYHC OEHSNAONS-0ED290E7 |
| Main Circuit Rating Current | 40A / 63A |
| Hlavný obvod Menovitý objemtage | 220V / 230V AC |
| Coil Voltage | 220V / 230V AC |
| Frekvencia | 50/60 Hz |
| Počet Poliakov | 2 |
| Konfigurácie kontaktov | 2NO, 2NC, 1NO1NC |
| Typ montáže | 35 mm DIN lišta |
| Špecifikácia splnená | UL (as per product data) |
9. Záruka a podpora
9.1 Informácie o záruke
This GEYA GYHC 2P Modular AC Contactor is covered by a standard manufacturer's warranty against defects in materials and workmanship. The specific duration and terms of the warranty may vary. Please retain your proof of purchase for warranty claims.
9.2 Technická podpora
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact the seller or authorized distributor from whom you purchased the product. Provide your product model number and purchase details for efficient support.